[email protected] +86 133 2121 6666 FDA · CE · RoHS · SGS Certified
Pmise VF-07

High Frequency for Vessel Diseases

Pmise VF-07

  • Two working modes, Pulse and Continuous, guarantee more comfort and obvious results
  • 0.01mm treatment Tip provides good epidermis protection and immediate telangiectasia sealing
  • Power board from USA guarantees stable treatment and long lifetime.
  • 12.1" LCD touch screen for easy operation.
  • Treatment Tip diameter is only 0.01mm which will not damage the epidermis.The vascular can be removed once.

Overview

Pmise VF-07 is a professional high-frequency vascular device built for the targeted treatment of superficial vascular lesions such as facial telangiectasia and small spider veins. It uses a fine, insulated needle tip to deliver high-frequency current straight to the enlarged capillary, coagulating and sealing the vessel while sparing the surrounding skin. It is part of the Pmise High Frequency for Vessel Diseases line and is intended for use by trained operators in clinics and aesthetic practices.

The system pairs an ergonomic handpiece with a large touchscreen console, so operators can adjust energy and switch between Pulse and Continuous modes without leaving the treatment position. This makes it a practical fit for busy clinics that see a steady flow of small vascular and benign proliferative concerns and need a device that is quick to set up between patients.

For a fuller picture of the conditions this class of device addresses, see our guide to facial telangiectasia and spider veins and the single telangiectasis treatment workflow.

How It Works

The VF-07 works by high-frequency electrothermal coagulation rather than by a laser wavelength. When the ultra-fine tip touches an enlarged capillary, high-frequency current concentrates at the point of contact and heats the vessel from within. That heat coagulates the hemoglobin and the endothelial cells that line the vessel wall, so the capillary is sealed on the spot instead of being cut or scraped.

The rationale for a fine tip and controlled energy is precision. Because the active area is only a fraction of a millimetre wide, the thermal effect stays inside the target vessel and the overlying epidermis is largely protected. Hemoglobin is highly responsive to heat, so the coagulation reaction happens quickly at the point of treatment; the treated tissue then sloughs off naturally over the following days as the skin heals. Pulse mode gives short, measured bursts for comfort on delicate areas, while Continuous mode suits operators who prefer a steady working current.

As a mains-powered high-frequency medical device, the VF-07 is designed to be run within the safety framework that governs high-frequency surgical equipment (see Sources). Operators control depth and effect through tip placement, dwell time and energy level, which is why the technology depends on trained hands rather than fixed automatic settings.

Applications

The VF-07 is suited to superficial vascular and small benign surface concerns treated point by point. Typical applications include:

  • Facial telangiectasia and small spider veins
  • Cherry angiomas and other small vascular spots
  • Minor vascular problems on the face and body
  • Benign proliferations such as milia, skin tags and flat warts
  • Age spots and sun spots

It is professional equipment intended for clinics, medspas and distributors serving them, and it is best used by operators trained in vascular and lesion work. A consultation and skin assessment should precede any session so the operator can confirm the concern is appropriate for high-frequency treatment.

Key Advantages

  • Two working modes, Pulse and Continuous, so operators can match energy delivery to the area and to patient comfort.
  • An ultra-fine treatment tip keeps the thermal effect focused on the vessel and helps protect the surrounding epidermis.
  • Immediate sealing of the treated capillary, so results are visible at the point of treatment and many small lesions can be handled in a single pass.
  • Stable imported power board for consistent output and a long service life.
  • Large touchscreen interface for straightforward parameter control and an efficient clinic workflow.

Specification

Output Power0-100% Adjustable ±10%
Output Frequency13.56MHz
Frequency1000-2000Hz (step 100Hz)
Treatment Tip0.01mm
Power Supply220V/50Hz 110V/60Hz ±10%
Working ModeContinuous/Pulse
Insurance StandardAC50V-120V ±10%
Input Power50W
Handpiece Length2m
LCD Screen12" touch screen

FAQ

What conditions is the Pmise VF-07 used for?

It is used mainly for superficial vascular lesions such as facial telangiectasia, small spider veins and cherry angiomas, and it also helps with small benign proliferations like milia, skin tags and flat warts, plus age and sun spots. It treats lesions point by point, so it suits small, defined targets rather than large diffuse areas. A trained operator should confirm suitability during consultation.

Is it safe for different skin types?

Because the VF-07 targets the vessel with a very fine tip rather than heating a broad area of pigment, it can be considered across a range of skin types, but suitability always depends on the individual lesion and skin. A patch or test point and a proper skin assessment are recommended before a full session. It is professional equipment and outcomes depend on correct operator technique.

How many sessions are needed?

Many small lesions respond in a single treatment, and the treated tissue then sloughs off naturally over the following days as the skin recovers. When repeat work is needed, sessions are usually spaced about a month apart to allow full healing. The exact plan depends on the number, size and depth of the lesions, which the operator judges case by case.

What about training and warranty?

The VF-07 is intended for trained clinic operators, and Pmise provides operating guidance and after-sales support so staff can use it safely and consistently. Warranty terms, spare tips and technical support are arranged through Pmise or an authorised distributor. Please contact us via the product line page for current warranty details and operator materials.