[email protected] +86 133 2121 6666 FDA · CE · RoHS · SGS Certified
Pmise MF-06

Multifunction

Pmise MF-06

    Overview

    The Pmise MF-06 is a floor-standing multifunction beauty machine that combines Intense Pulsed Light (IPL) and Radio Frequency (RF) in one platform, giving clinics and salons a single system for hair removal, skin rejuvenation, and vascular and pigment work. It is professional equipment intended for use by trained operators, and it suits practices that want to cover several popular treatments without buying a separate device for each one.

    The machine pairs a filter-changeable IPL handpiece with a cooling RF handpiece, so an operator can move from light-based sessions to RF skin tightening within the same appointment flow. Buyers looking at the wider range can compare it with other systems on the Multifunction equipment page.

    For background on how these combined platforms are built and where they fit in a treatment menu, see our multifunction beauty equipment guide.

    How It Works

    The MF-06 works on the principle of selective photothermolysis, first described by Anderson and Parrish in 1983. Light of a chosen wavelength range is absorbed more strongly by a target such as melanin in a hair follicle or hemoglobin in a small vessel than by the surrounding skin, so heat builds where it is wanted while nearby tissue stays cooler. The IPL handpiece uses interchangeable filters to shift the delivered wavelength band toward the target for each application, which is why one handpiece can address hair, pigment, and vascular concerns.

    The RF side heats water in the deeper skin layers. This warming is used to encourage tissue contraction and a gradual collagen response, which is the mechanism behind skin tightening and texture work. Combining IPL and RF, often called E-Light, lets the RF energy pre-warm tissue so the light step can work at a comfortable light level rather than relying on light alone.

    A sapphire contact-cooling window on the IPL handpiece protects the skin surface during pulses. To read more about how the light and RF steps are combined in practice, see our overview of IPL and E-Light treatments.

    Applications

    The MF-06 is built for busy aesthetic practices that want broad coverage from one platform. Typical applications include:

    • Hair removal on the face and body
    • Skin rejuvenation and overall tone improvement
    • Reduction of freckles and other benign pigmented marks
    • Treatment of small vascular lesions and broken capillaries
    • Support for acne-prone skin
    • RF-based skin tightening and wrinkle softening

    It suits clinics, medical spas, and distributors serving them who need a versatile workhorse rather than a single-purpose laser. A trained operator should assess each client and set parameters to skin type and treatment area before any session.

    Key Advantages

    • Two technologies in one cabinet: a filter-changeable IPL handpiece plus a cooling RF handpiece, so the system helps improve several concerns from one console.
    • The G+E type IPL handpiece accepts multiple filters, letting the same handpiece be tuned toward hair, rejuvenation, or vascular work.
    • Sapphire contact cooling on the IPL handpiece helps keep the skin surface comfortable during pulses.
    • The RF handpiece delivers steady, even output, which supports predictable, controlled sessions.
    • Foot pedal and button switch control give operators a choice of working styles.
    • Serviceable shell and inner layout designed for easier maintenance, which matters for uptime in a commercial setting.

    Specification

    Handpiece Type: G+E type

    Spot Size: 8mm×40mm

    Filter Wavelength: HR 610-1200nm,

    VR 585-1200nm,

    SR 530-1200nm,

    PR 560-1200nm (optional),

    AR 430-1200nm (optional)

    Pulse Number: 1-10T

    RF Duration: 0.1-3.0s adjustable

    RF Frequency: 2.64MHz

    Handpieces: RW-VI (Cooling Mono-polar & Bi-polar RF)

    Mono-polar: ¢15mm, ¢25mm, ¢45mm

    Bi-polar: ¢25mm, ¢45mm

    RF Time: 0.1-20s

    Cathode Pads: 200mmx138mm (Stainless Steel)

    Cooling: Air, Water and Semi-conductor

    Energy Density: 20-50J/cm²

    Shot Interval: 3-5s

    1st –pulse Width: 0.1-10ms

    Sub-pulse Width: 0.1-10ms

    1st –pulse Interval: 1-20ms

    Sub –pulse Interval: 1-20ms

    Cooling Temperature: -2℃~0℃

    RF Power: 120W (Max)

    RF Working Mode: Continuous/ Pulse

    RF Delay: 0.1-20s

    Power Supply: AC 220V 50Hz;

    AC 110V 60Hz

    Insurance Standard: Max10A

    Net Weight: 45kg

    Gross Weight: 56kg

    Dimensions (before packaged):52x43x104cm3

    Dimensions (after packaged):59x57x128cm3

    FAQ

    What concerns can the MF-06 treat?

    It is a multifunction platform covering hair removal, skin rejuvenation, pigmented marks such as freckles, small vascular lesions, acne-prone skin, and RF skin tightening. Because it combines IPL and RF, one machine can address concerns that would otherwise need several devices. A trained operator selects the handpiece, filter, and settings appropriate to each client and area.

    Which skin types is it suitable for?

    IPL-based treatment is generally best suited to lighter and mid-range skin tones, and settings must be matched to the client's Fitzpatrick skin type. Darker skin carries more risk with light-based energy, so a careful test and conservative parameters are important. The operator should always assess skin type and history before treating and follow accepted screening practice.

    How many sessions are usually needed?

    Light and RF treatments are typically delivered as a course rather than a single visit, with intervals between sessions so the skin can respond and recover. The exact number depends on the concern, the area, the client's skin, and their goals. Results build gradually, so operators should set realistic expectations and plan a suitable schedule for each individual.

    What about safety, training, and warranty?

    The MF-06 is professional equipment for trained operators only. It ships as an E-Light system that has been through EMC compliance testing, and correct use depends on proper operator training and following the manual. For warranty terms, spare tips, and operator training options, contact the Pmise team through the site so we can match support to your market.