Pmise VF-01
- COOL01 can provide continuous epidermis cooling protection throughout the phototherapy treatment, which lowers the risk of thermal damage.
- Combined with all kinds of phototherapy device which helps avoid epidermis lesions,
- Air filtering& drying device protects the treatment from the interference of water fume.
- Temperature is adjustable, -20℃(Min).
- COOL01's powerful cooling protection makes it possible to use higher energy density on deeper target tissue.
Overview
Pmise VF-01 is a continuous epidermis cooling device built for the High Frequency for Vessel Diseases line, where it protects the skin surface while light-based and high-frequency systems treat vascular conditions. It delivers a steady stream of chilled, filtered air onto the treatment area, so the operator can work on dilated vessels and telangiectasia with a lower risk of thermal injury to the epidermis.
In vascular work the target sits inside the vessel, not on the surface. VF-01 keeps the epidermis cool and comfortable so more of the delivered energy can act where it is needed while the skin above stays protected. This is professional equipment intended for trained operators in clinics and aesthetic practices, used together with a compatible phototherapy or high-frequency handpiece rather than on its own.
The device fits naturally into the wider High Frequency for Vessel Diseases range and pairs well with treatment protocols for facial redness and spider veins. For clinical background on those indications, see our guide to facial telangiectasia and spider veins.
How It Works
VF-01 uses a refrigeration unit to generate a continuous flow of cold, dried air that is directed at the skin before, during and after a vascular treatment pulse. The cooling temperature is adjustable, reaching well below zero at its lowest setting, which lets the operator match the level of protection to the patient's skin type and the energy being used.
The rationale comes from selective photothermolysis, the principle described by Anderson and Parrish in 1983. Vascular treatments aim to heat oxyhemoglobin inside the vessel, which absorbs strongly in the visible range, while sparing the surrounding tissue. Because the epidermis also absorbs some of the incoming energy and can heat up, surface cooling helps keep the skin below the threshold of thermal damage. As our internal skin-science notes put it, good epidermal cooling keeps the target tissue much hotter than the epidermis, which is what makes higher, more effective settings safe to use.
An integrated air filtering and drying stage removes moisture from the cold air so that water vapor does not condense on the skin or interfere with the optics of the paired device. The result is stable, repeatable cooling across a full session.
Applications
VF-01 is a supporting cooling device for practitioners running vascular and general phototherapy protocols. It suits clinics and distributors who already offer, or plan to offer, treatments for surface vascular conditions and want to raise both comfort and safety.
- Epidermal protection during treatment of facial telangiectasia and single dilated vessels
- Cooling support for rosacea-related redness and general facial flushing protocols
- Comfort and surface protection during spider vein and small vascular lesion work
- Pain reduction and epidermal cooling across compatible phototherapy sessions
- General laser and IPL procedures where higher energy on a deeper target calls for stronger surface cooling
For a focused clinical workflow, see our solution page on treating single telangiectasis.
Key Advantages
- Continuous cooling throughout the session, not just in short bursts, which lowers the risk of thermal damage to the epidermis
- Adjustable temperature, so protection can be tuned to skin type and the energy level in use
- Air filtering and drying stage that keeps water fume from interfering with the treatment or the paired optics
- Non-contact cool air that avoids pressing on fragile treated vessels
- Works alongside a wide range of phototherapy and high-frequency handpieces, protecting existing equipment investment
- Cooling headroom that lets trained operators use higher, more effective energy on deeper targets with the surface still protected
- Stand-mounted, mobile format suited to a busy treatment room
Specification
| Mode | COOL01 |
|---|---|
| Voltage | AC220V/60Hz |
| Power Consumption | 1kva |
| Working Temperature | -20℃±5℃ |
| Initiating Time | 15 minutes (Max) |
| Operating Mode | continue-flow |
| Auto mode 1 | 1-2-3-4-5-4-3-2-1-2... |
| Auto mode 2 | 1-2-3-2-1-2-3-2-1-2... |
| Auto mod 3 | 3-4-5-4-3-5-4-3-4... |
| Auto Mode | slow |
| Switch Time | 6s |
| Fast switch time | 3s |
| Time Setting | 1-99minutes±1 minutes,common setting: 10minutes |
| Size | 348*470*1051mm3 |
| Weight | 63.4kg |
FAQ
What does VF-01 actually do in a vascular treatment?
It does not treat vessels on its own. VF-01 is a cooling device that blows continuous cold, filtered air onto the skin while a paired phototherapy or high-frequency handpiece treats the vessel. The cooling protects the epidermis and reduces pain, which lets the operator use effective energy settings more safely on conditions such as facial telangiectasia and general redness.
Which skin types can it be used with?
Surface cooling is helpful across a broad range of skin types because the operator can adjust the temperature to match. Darker skin, which holds more melanin in the epidermis, generally benefits from strong surface cooling. Final suitability always rests with the treating clinician, who assesses each patient and chooses parameters on the paired treatment device.
How many sessions will a patient need?
That depends entirely on the paired treatment system and the condition being addressed, not on the cooler. Surface vascular conditions often need a course of sessions spaced weeks apart. VF-01 simply supports comfort and epidermal safety during each of those sessions. Clinics should follow the protocol for their primary vascular device.
What about training, safety and warranty?
VF-01 is professional equipment for trained operators only. It should be used with a compatible treatment system and in line with the operator's own clinical protocols. We provide operating documentation and distributor support, and warranty terms are confirmed at the point of order. Contact our team for full commercial and after-sales details.