[email protected] +86 133 2121 6666 FDA · CE · RoHS · SGS Certified
Pmise LN-02

Pmise LN-02

  • There is no recurrence after the treatment, efficient.
  • No side effects, safe.
  • Also works on skin rejuvenation, multifunctional.
  • No injury during the treatment, but only warm feeling, comfortable.
  • Each treatment takes only 5-10 minutes, fast.

Overview

The Pmise LN-02 is a long-pulse Nd:YAG laser built for the professional treatment of nail fungus (onychomycosis). It delivers a 1064nm near-infrared beam through a fiber handpiece so a trained operator can direct controlled heat into the nail plate and nail bed, where the fungal colony lives. It belongs to our Long Pulse Nd:YAG laser for Fungus line and is aimed at clinics, podiatry practices, and medical aesthetic distributors.

Unlike topical creams and oral drugs that struggle to reach fungus trapped under a thick nail, the LN-02 wavelength passes through the nail and targets the colony directly. Each session is short, and the device supports repeat visits over a treatment course. If you are comparing pulse formats before buying, our guide on long-pulse versus Q-switched Nd:YAG explains why a millisecond long pulse suits thermal fungus work rather than pigment shattering.

How It Works

The LN-02 works on the principle of controlled photo-thermal heating. Its 1064nm wavelength sits in the near-infrared range, which penetrates the nail plate well and is only weakly absorbed by surrounding tissue, so energy can reach the fungal colony under and within the nail. As the laser pulses build heat, the local nail temperature rises to around 50 degrees Celsius, the range in which fungal structures are damaged while the operator keeps the surface tolerable.

The long-pulse format matters here. A pulse in the millisecond range spreads energy over time, producing a steady thermal effect suited to warming a volume of tissue rather than the ultra-short, high-peak bursts used for tattoo and pigment work. This gradual delivery, combined with fiber beam delivery to the handpiece, gives the clinician a warm, buildable sensation to work from. The underlying idea of matching wavelength and pulse duration to a target so heat concentrates where it is wanted traces back to the selective photothermolysis principle described by Anderson and Parrish in 1983. Effective cooling and gradual heating together let the operator raise nail temperature into the useful range while managing patient comfort.

Applications

The LN-02 is professional equipment operated by trained clinicians. Its primary indication is fungal nail infection, and the long-pulse 1064nm platform is also used across related aesthetic and vascular work.

  • Onychomycosis (fungal infection of finger and toe nails)
  • Support for restoring a clearer, more normal-looking nail over a treatment course
  • Skin rejuvenation applications on suitable platforms
  • Vascular and telangiectasia work on long-pulse Nd:YAG systems, as covered in our single telangiectasis solution

It suits foot-care and podiatry clinics, dermatology and medical aesthetic centers, and distributors serving them. Suitability for an individual patient, including skin type and any contraindications, should be assessed by the treating clinician before a session.

Key Advantages

  • Reaches fungus through the nail: the 1064nm near-infrared beam penetrates the nail plate to heat the colony directly, something topical products often cannot do.
  • Controlled long-pulse heating: millisecond pulses build heat gradually toward the target temperature rather than delivering a harsh single shock.
  • Comfort-focused workflow: patients typically report only a warm feeling during treatment, and each session is short.
  • Fiber beam delivery: energy travels through a fiber to a handpiece for flexible, precise positioning over individual nails.
  • Built for clinic use: a straightforward operating interface and a design intended for repeated daily sessions.
  • No consumables to replace per shot, which helps keep running costs predictable for busy practices.

Specification

Wavelength1064nm±10nm
Working ModePulse mode
Energy Density300J/cm²
Pulse Width1ms-50ms
Beam DeliveryFiber
Energy (single pulse)15J/cm² -300J/cm²
Frequency1/3-1Hz
Spot Size0.4mm²
Input Power1600W
Power SupplyAC 220±10% 50Hz;
Insurance StandardMax 10A

FAQ

What conditions is the LN-02 used for?

Its main use is nail fungus, or onychomycosis, in finger and toe nails. The long-pulse 1064nm platform is also applied to skin rejuvenation and vascular work on suitable configurations. It is professional equipment, so the treating clinician decides whether a given patient and indication are appropriate before starting.

Is it safe for all skin types?

Nd:YAG at 1064nm is generally considered friendly across a wide range of Fitzpatrick skin types because it is only weakly absorbed by melanin. That said, safety depends on correct settings, cooling, and operator technique. Every patient should be assessed individually, and contraindications must be ruled out by the clinician before treatment.

How many sessions are needed?

Fungal nail treatment is usually a course rather than a single visit, because a healthy nail has to grow out to replace the affected one. Each session itself is short, often only a few minutes per area. The exact number and spacing of sessions should be planned by the clinician based on how the nails respond over time.

What about training and warranty?

Because this is a professional laser device operated by trained staff, we provide operator guidance and documentation with each unit, and warranty and after-sales support terms are confirmed at the time of order. Please contact our team for current warranty length, spare-part availability, and training options in your region.