Pmise CF-07
- Adopted American RF-excited CO2 laser generator (60W), brings highest treatment performance and less complications.
- German CPG which provides 80μm focal spot diameter, ensures even treatment effect.
- 3 kinds of spot lenses meet different area treatment requirements.
- Fixed focal spot lens enables 80um spot diameter which leads to deepest peeling depth without changing energy.
- Adjustable focal spot lenses can be freely used for deep or shallow skin tissues.
Overview
The CF-07 is a professional CO2 fractional laser built on the 10600nm carbon dioxide wavelength, designed for clinics and aesthetic practices that treat scars, wrinkles, and photo-aged skin. It is a resurfacing platform: the beam is delivered in a fractional pattern so that only a fraction of the skin is treated in each pass, leaving healthy tissue between the treated points to speed recovery.
Because the carbon dioxide wavelength is strongly absorbed by water in skin, the CF-07 works on almost any tissue type without relying on a specific pigment. This makes it a versatile choice for a distributor or clinic that wants one device to cover resurfacing, scar revision, and minor cosmetic surgery tasks. If you are still comparing platforms, our guide on how to choose a fractional CO2 laser walks through the trade-offs, and you can see the full range on the Ultrapulse CO2 Fractional Laser (10600nm) category page.
The CF-07 is professional equipment intended to be used by trained operators under appropriate clinical protocols. Exact device parameters are listed in the Specification table below.
How It Works
The CF-07 emits infrared light at 10600nm, a wavelength that water absorbs very efficiently. Since skin is largely water, the energy is taken up right at the surface and converted to heat in a thin layer, which is the physical basis for controlled ablation and resurfacing. This targeting of a tissue chromophore by wavelength is the principle of selective photothermolysis first described by Anderson and Parrish.
In fractional mode the beam is split into a grid of tiny points. Each point creates a microscopic thermal channel, a small column of ablated and coagulated tissue, while the skin immediately around it stays intact. That surrounding untreated tissue acts as a reservoir of healthy cells that drives faster healing. As the micro-injuries repair, the body lays down and remodels new collagen, which is what tightens skin and softens the appearance of scars and lines.
Adjusting energy on this class of device is done mainly by changing pulse width rather than raw power, so the operator can move from shallow, gentle passes to deeper peeling by selecting the right lens and settings. Interchangeable focal-spot lenses let the same platform handle broad resurfacing or fine work on delicate zones. The continuous, ultra-pulse, and fractional output modes give the operator control over how much heat is deposited and how deep it reaches.
Applications
The CF-07 suits clinics, dermatology practices, and cosmetic surgery rooms that need one resurfacing platform for a broad indication list. Typical applications include:
- Fine lines, deeper wrinkles, and overall skin tightening for photo-aged skin
- Scar improvement, including acne scars, surgical scars, and burn scars
- Stretch marks and loose or rough skin texture
- Enlarged pores and general skin rejuvenation and resurfacing
- Epidermal pigmented lesions such as freckles and age spots
- Minor cosmetic-surgery tasks such as small skin tags, warts, and selected lesion removal in ultra-pulse and continuous modes
Because scar work is one of the most requested uses, see our scar treatment solution for protocol context. Suitability for a given patient and skin type should always be assessed by a trained clinician.
Key Advantages
- RF-excited CO2 laser source for consistent output and a long, stable service life compared with glass-tube designs
- Fractional delivery treats a fraction of the skin per pass, so downtime and complication risk are lower than fully ablative resurfacing
- Three interchangeable focal-spot lenses, including a fixed lens for the deepest peeling, an adjustable lens for shallow or deep work, and a roller lens for orbital, perioral, and nose-wing areas
- Multiple output modes (continuous, ultra-pulse, and fractional) let one device cover resurfacing and minor surgery
- Energy is tuned through pulse width, giving the operator fine control over ablation depth without swapping the whole configuration
- Professional build intended for repeatable clinical workflow in a busy practice
Specification
| Spot diameter | 80-2000um (continuously adjustable) |
|---|---|
| Laser Power | 60W |
| Output Mode | CW, UP & CPG |
| Pulse Energy | 10mj-200mj (step 2mj) |
| Pulse Interval | 1ms-100ms (step 1ms) |
| Pulse Width | 0.067ms-6.7ms |
| Dimension (after package) | 68x57x144 cm³ |
| Gross Weight | 94kg |
FAQ
What conditions is the CF-07 used for?
It is a CO2 fractional laser used mainly for skin resurfacing: fine lines and wrinkles, acne and surgical scars, stretch marks, enlarged pores, and epidermal pigmentation such as freckles and age spots. In ultra-pulse and continuous modes it also handles minor cosmetic-surgery tasks. A trained clinician should confirm that a specific indication is appropriate for each patient.
Is it safe for all skin types?
CO2 lasers target water rather than pigment, so they are not limited to one skin color, but darker skin carries a higher risk of post-treatment pigment change. Because of this, treatment settings, test spots, and aftercare should be selected by a trained operator based on the individual patient. This is professional equipment, not a home or walk-in device.
How many sessions are needed?
It depends on the indication and how the skin responds. Resurfacing and scar work are usually done as a course of sessions spaced weeks apart to allow full healing and collagen remodeling between treatments. The treating clinician sets the plan after assessing skin type, the target concern, and results from earlier passes.
What about training and support for distributors?
Because outcomes depend heavily on operator technique and correct settings, the CF-07 is intended for use by trained professionals. Pmise supports distributors and clinics with product training and after-sales service. Contact us for current warranty terms, spare-part supply, and operator training arrangements for your market.